ADSS power optical cable: technological innovation and operation and maintenance security advance together to support the stable development of power communications


Redefining Durability: Engineered for Extreme Resilience
·High-quality high-density raw materials, soft and tough, odorless and environmentally friendly

Our ADSS cables use ceramic particle PE/AT sheath materials to achieve IEC 60794-1-2 E13 certified UV resistance (over 3,000 hours of xenon arc test). Field data from Saudi Arabia's 138kV power grid project showed that at 50°C+ desert sunlight, the annual attenuation increased by only 0.12dB/km, 68% lower than the industry average.


Electromagnetic Neutral Architecture
·Through GFRP (Glass Fiber Reinforced Plastic) central strength members and 100% non-metallic aramid yarn layers, our cables maintain ≤0.01μV electromagnetic induction at 1m from 750kV AC lines (per IEEE 1590 compliance). This enables safe co-location with EHV corridors without signal distortion.


Closed-Loop Sustainable Production

Manufacturing processes adhere to ISO 14067 carbon footprint protocols, featuring:

  • ·92% recycled HDPE content in cable jackets

  • ·Water-based ink marking systems (0 VOC emissions)

  • ·Scrap aramid fiber repurposing into fire-resistant insulation mats


Reference outer diameter

(mm)

Reference outer diameter kg/km

Recommended daily maximum working tension
kN

Maximum allowable working tension
kN

Breaking strength
kN

Tensile element

Cross section

mm

Modulus of elasticity kN/mm*2

Thermal expansion coefficient

x10K

Suitable for the weather conditions corresponding to the gear spacing

PE sheath 

AT sheath

A

B

C

D

12.5

125

136

1.5

4.0

10

4.6

7.6

1.8

160

100

140

100

13

132

142

2.3

6.0

15

7.6

8.3

1.5

230

150

200

150

13.6

145

156

3.6

10.0

24

13.8

10.8

1.2

370

250

350

250

14.9

171

185

6.8

18.0

45

22

16.4

0.6

570

380

550

380

15.5

190

204

9.0

26.0

60

32.2

19.1

0.1

750

530

750

510

16.8

226

242

15.5

41.0

103

48

24

-0.4

1000

750

1000

760


Global Case Studies: ADSS in Action

Canadian Smart Grid Upgrade
Deployed 24-core ADSS across 180km of 230kV lines, enabling real-time fault detection for 50+ substations. Result: 32% faster outage response.

Swedish Wind Farm Integration
Custom 96-core cables with -50°C Arctic-grade sheathing connected offshore turbines to SCADA systems, surviving -45°C winters and 35m/s winds.

South African Rural Electrification
Hybrid ADSS/OPGW networks brought high-speed comms to 200+ villages, with anti-rodent jackets preventing wildlife damage.

 


Why Partner With Us?


10+ years of grid expertise: Serving over 50 countries, including partnerships with ENEL, State Grid and National Grid Corporation.

Excellent certifications: Meets IEC 60794, IEEE 1138 and CENELEC HD 620 standards.

Quick customization: 6-144 core configurations, flame retardant/anti-corrosion options, 15-day lead time.


Post time: 2024-08-14 15:45:46
  • Previous:
  • Next:
  • Leave Your Message