Redefining Durability: Engineered for Extreme Resilience
·High-quality high-density raw materials, soft and tough, odorless and environmentally friendly
Our ADSS cables use ceramic particle PE/AT sheath materials to achieve IEC 60794-1-2 E13 certified UV resistance (over 3,000 hours of xenon arc test). Field data from Saudi Arabia's 138kV power grid project showed that at 50°C+ desert sunlight, the annual attenuation increased by only 0.12dB/km, 68% lower than the industry average.
Electromagnetic Neutral Architecture
·Through GFRP (Glass Fiber Reinforced Plastic) central strength members and 100% non-metallic aramid yarn layers, our cables maintain ≤0.01μV electromagnetic induction at 1m from 750kV AC lines (per IEEE 1590 compliance). This enables safe co-location with EHV corridors without signal distortion.
Closed-Loop Sustainable Production
Manufacturing processes adhere to ISO 14067 carbon footprint protocols, featuring:
-
·92% recycled HDPE content in cable jackets
-
·Water-based ink marking systems (0 VOC emissions)
-
·Scrap aramid fiber repurposing into fire-resistant insulation mats
Reference outer diameter(mm) |
Reference outer diameter kg/km |
Recommended daily maximum working tension
|
Maximum allowable working tension
|
Breaking strength
|
Tensile elementCross sectionmm |
Modulus of elasticity kN/mm*2 |
Thermal expansion coefficientx10K |
Suitable for the weather conditions corresponding to the gear spacing |
||||
PE sheath |
AT sheath |
A |
B |
C |
D |
|||||||
12.5 |
125 |
136 |
1.5 |
4.0 |
10 |
4.6 |
7.6 |
1.8 |
160 |
100 |
140 |
100 |
13 |
132 |
142 |
2.3 |
6.0 |
15 |
7.6 |
8.3 |
1.5 |
230 |
150 |
200 |
150 |
13.6 |
145 |
156 |
3.6 |
10.0 |
24 |
13.8 |
10.8 |
1.2 |
370 |
250 |
350 |
250 |
14.9 |
171 |
185 |
6.8 |
18.0 |
45 |
22 |
16.4 |
0.6 |
570 |
380 |
550 |
380 |
15.5 |
190 |
204 |
9.0 |
26.0 |
60 |
32.2 |
19.1 |
0.1 |
750 |
530 |
750 |
510 |
16.8 |
226 |
242 |
15.5 |
41.0 |
103 |
48 |
24 |
-0.4 |
1000 |
750 |
1000 |
760 |
Global Case Studies: ADSS in Action
Canadian Smart Grid Upgrade
Deployed 24-core ADSS across 180km of 230kV lines, enabling real-time fault detection for 50+ substations. Result: 32% faster outage response.
Swedish Wind Farm Integration
Custom 96-core cables with -50°C Arctic-grade sheathing connected offshore turbines to SCADA systems, surviving -45°C winters and 35m/s winds.
South African Rural Electrification
Hybrid ADSS/OPGW networks brought high-speed comms to 200+ villages, with anti-rodent jackets preventing wildlife damage.
![]() |
Why Partner With Us?
10+ years of grid expertise: Serving over 50 countries, including partnerships with ENEL, State Grid and National Grid Corporation.
Excellent certifications: Meets IEC 60794, IEEE 1138 and CENELEC HD 620 standards.
Quick customization: 6-144 core configurations, flame retardant/anti-corrosion options, 15-day lead time.
Post time: 2024-08-14 15:45:46